Follow
International Journal of Current Microbiology and Applied Sciences (IJCMAS)
IJCMAS is now DOI (CrossRef) registered Research Journal. The DOIs are assigned to all published IJCMAS Articles.
Index Copernicus ICI Journals Master List 2022 - IJCMAS--ICV 2022: 95.28 For more details click here
National Academy of Agricultural Sciences (NAAS) : NAAS Score: *5.38 (2020) [Effective from January 1, 2020] For more details click here

Login as a Reviewer


See Guidelines to Authors
Current Issues
Download Publication Certificate

Original Research Articles                      Volume : 7, Issue:12, December, 2018

PRINT ISSN : 2319-7692
Online ISSN : 2319-7706
Issues : 12 per year
Publisher : Excellent Publishers
Email : editorijcmas@gmail.com /
submit@ijcmas.com
Editor-in-chief: Dr.M.Prakash
Index Copernicus ICV 2018: 95.39
NAAS RATING 2020: 5.38

Int.J.Curr.Microbiol.App.Sci.2018.7(12): 2476-2481
DOI: https://doi.org/10.20546/ijcmas.2018.712.281


Ergonomic Evaluation and Comparison of Existing and Modified Power Weeder
Suryakanta Khandai1, Ashok Tripathi1, Virendra Kumar2, Ashish Kumar Kerketta1 and Surendra Pal1
1Department of Farm Machinery and Power Engineering, VSAET, SHUATS, India
2International Rice Research Institute, Los Banos, Philippines
*Corresponding author
Abstract:

Power weeder uproots the weeds between the paddy crop rows with 25 cm row to row distance, in addition to, it keeps the soil surface loose for better soil aeration and water intake capacity. In this study modification was done to existing STIHL power weeder which is operated in line with the attachment of float and covering structure on weeding wheel to avoid mud splash over operator. In this study, the existing weeder and modified weeder has studied ergonomically. 3-axis accelerometer, showed that modified weeder has less vibration of 1.984 m/s2 from the existing weeder. It was found that average final reading of heart rate for modified power weeder was 101.7 bpm with average initial reading of 95.4 bpm which is comparatively less for existing power weeder having 107.3 bpm with average initial reading of 96.5 bpm. The oxygen consumption rate after completion of the operation for modified weeder was 88.8 l/min and for existing weeder is 91.3 l/min. The noise level for modified weeder was 85.55 db and existing weeder was 89.03 db.


Keywords: Power weeder, Ergonomic, Vibration, Noise, Heart rate, Oxygen consumption rate

Download this article as Download

How to cite this article:

Suryakanta Khandai, Ashok Tripathi, Virendra Kumar, Ashish Kumar Kerketta and Surendra Pal. 2018. Ergonomic Evaluation and Comparison of Existing and Modified Power Weeder.Int.J.Curr.Microbiol.App.Sci. 7(12): 2476-2481. doi: https://doi.org/10.20546/ijcmas.2018.712.281
Copyright: This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike license.

Citations